3.30. LISTFC: List formated reflection data

outputspecify items to be listed
formatspecify formats of items to be listed
pscaleprint scales of items to be listed
scalestructure factor scale
maxhklspecify max h, k, l and min/max sin / to be listed

LISTFCOption CodeArg Def
 hkl indices listed ind n indices listed (1 or 3)1
 hkl sort order [a] ord hkl hkl chars in order slo/med/fastbdf
 list rcode flags nfl  rcode flags will not be listed 
   fla f four chars for rcodes 2345-***
 output pch file pun  punch data (80 chars max) 
   npun  no punch output 
 output line width [b] wid w chars per output linelocal default
 output lines/page [b] lin l lines per page headerlocal default
 dataset number dse n  1
 print void items vbl  print void items as blankno
Notes:
a. Only used if the SORTRF sort order code is not on the bdf. If data is unsorted, ind 3 is recommended because LISTFC does not sort reflection data!
b. These parameters may be used to output one reflection per line for use with external software. To do this, set wid to the number of chars in one reflection and lin to a very large number.

output [a]1-20items output (as codes or bdf ID numbers) 
Notes:
a. The item specification for field 1 MUST be either hkl or 1 . Alphabetic codes accepted are those defined for ADDREF bdfin (with the exception of all and Friedel reflection packets) and the addition of f2cl and ical for outputting calculated intensity I and F2cal and ffrel, fsigf, ff2rl and fsgf2 for Friedel data. Typical codes are frel , fcal , sigf , pcyc or pdeg . Each item must be specified in order of output. A maximum of 20 items may be entered.
NOTE that if the output line is not entered hkl frel fcal and sigf will be listed.

format1-20format of output items as 'Inn' or 'Fnn.m'I3 for hkl, else I5

pscale1-20print scale of output items [a]1 for hkl, else 10
Notes:
a. Defaults only apply if output line not entered.

scale1Frel scale1.0
 2scale group number1

maxhkl1-3max |h|, |k|, |l| output9999
 4min sin/ output0
 5max sin/ output2