This compendium of XAFS beamlines is mantained by the Commission on XAFS of the IUCr as a service to the scientific community. We list beamlines on which measurements of XAFS, XMCD and related techniques, both in the soft and in the hard x-ray regions, are possible; the widest possible range of applications is considered. Both presently operating beamlines and those which are in the construction, commissioning or design phase are included.

See our list of acronyms.

The data is listed to the best of our knowledge; most of it has been obtained from facility websites and in some
cases it has been checked by members of the IUCr Commission on XAFS, staff scientists or expert users.
We wish to thank Santiago J. A. Figueroa (LNLS), E. Farquhar (NSLS) and S. Heald (APS) for helpful comments.

We welcome corrections and updates, which should be sent to Giuliana Aquilanti and Masao Tabuchi

 

ALS (Berkeley, CA, USA)

 

 

ALS

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

4.0.2

0.1 - 2

1013

0.1 x 0.1
XMCD, XMLD,
XANES

Operational

6.3.1

0.3 - 2

1011

0.05 x 0.5
XAFS, XMCD, XMLD

Operational

7.0.1

0.1 - 0.8
----
0.08 - 1.2

108 - 109
----
3 x 1012

300  nm
------
50 μm

Surface science, XANES and PES microscopy
----
Surface science, PES, XANES

Operational

8.0.1

0.08 - 1.25

> 1011

0.03 x 0.1 mm

  XANES

Operational

10.3.2

2.5 - 17

1010

5 x 5 μm
micro XANES

Operational

11.0.2

0.1 - 2
-------
0.13 - 2

1012 - 1013
--------
109

10 μm
------
20 nm
micro-XANES, PES in
non-UHV environment
--------
XANES microscopy

Operational

ALS updated 11 February 2012

APS

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

 2-ID-D  5 - 30  4 ×109  2 μm × 2 μm microXAFS   Operational

4-ID-C

 

0.5 - 3

1 x 1012

0.1 × 0.1
XMCD, XMLD, PES,
magnetic scattering

Operational

4-ID-D

 

0.5 - 50

3 x 1013

0.1 x 0.22
XMCD, magnetic scattering

Operational

5-BM-D

 

4.5 - 80

5 ×1011

0.5 x 30
General purpose XAFS, in polymer and materials science

Operational

 7-ID-B,C,D  6 - 21  8 ×1012  10 μm ×10 μm time resolved XAFS  Operational 

9-BM-B,C

 

2.1 - 23

1 x 1011

0.5 x 0.5
General purpose XAFS, in materials science and chemistry

Operational

10-ID-B

 

4.3- 90

1011 - 1013

2 μm ×2 μm minimum
General purpose XAFS, dilute elements, DAFS, XAFS microscopy in materials science

Operational

 10-BM-B  3 - 200    3 × 50 General purpose XAFS   Operational

11-ID-D

 

4 - 40

1 x 1012

0.5 x 1
General purpose XAFS in chemistry, materials science, geoscience and physics. DAFS, time resolved XAFS

Operational

12-BM-B

 

4.5 - 24

5 × 1010

1 x 1
General purpose XAFS in chemistry, materials science, geoscience and physics

Operational

13-BM-D

 

4.5 - 70

109

0.01 x 0.03
General purpose XAFS, high pressure, geoscience

Operational

13-ID-C,D

 

4 - 45

1011 - 1013

0.06 x 0.02 to
0.002 x 0.002
General purpose XAFS, high pressure, geoscience

Operational

 16-BM-D 6 - 70   3 × 109  5 μm ×5 μm  XAFS at high pressure  Operational

18-ID-D

 

3.5 - 35

2 x 1013

0.05 x 0.5
General purpose, microXAS in the life sciences

Operational

20-BM-B

 

2.7- 30

1 x 1011
---------------
2 x 108

0.5 x 0.2
---------------
0.005 x 0.005
General purpose XAFS, microXAFS in materials, environmental and geological science

Operational

20-ID-B,C

 

3 - 50

1011  - 1013

2 μm × 2 μm minimum
General purpose XAFS, DAFS, microXAFS, time resolved XAFS in materials, environmental and geological science 

Operational

 APS checked 11 February 2012

CAMD

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

DCM

0.9 - 20

.

.
General purpose

Operational

  CAMD checked 11 February 2012

 

CLS

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

VLS-PGM

0.01 - 0.25

2 x 1012

0.5 x 0.5
XAS, XEOL

Operational

SGM

0.25 - 2

4 x 1012

0.1 x 1
XAS, PES, XEOL

Operational

HXMA

5 - 40

6 x 1011

0.5 x 0.1
General purpose XAFS

Operational

REIXS

0.08 - 2

1 x 1013

0.01 x 0.06
XAS, XMCD, XES, RIXS

Commissioning

SXRMB

1.7 - 10

1 x 1011

0.3 x 0.3
XAS, XMCD, PES, XEOL

Operational

VESPERS

6 - 30

2 x 109 - 4 x 1011

2 mm spot
microXAS

Operational

  CLS checked 11 February 2012

LNLS

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

SGM

 

0.25 - 1

.

0.5 x 0.5
XANES, XMCD, PES

Operational

SXS

 

0.9 - 5.5

.

1 x 3
XAFS, PES, XMCD

Operational

 XAFS1  4 -24
 109  1 x 1
 General purpose XAFS
 Operational
 XAFS2  4 - 17
 1010  0.25 x 0.45
 General purpose XAFS Operational

DXAS

 

5 - 14

2 x 1011

0.15 x 0.2
Dispersive set-up

Operational

 PGM  0.1 - 1.5  .  .  XAFS, XMCD, PES  Operational
  TGM 0.007 - 0.33   1011  0.5 x 2 XAFS, PES  Operational 

 LNLS Checked 5 November 2014

NSLS

Note: NSLS will shutdown on September 30th, 2014; stay tuned for information on NSLS-II 

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

U1A

0.1 - 1

.

1 x 2
XANES, surface science

operational

U4B

0.02 - 1.2

1 x 1011

.
XMCD, PES, XAS,
Res. Mag. Scattering

operational

U7A

0.18 - 1.6

2 x 1011

.
XANES, PES,
surface science

operational

U12A

0.1 - 0.8

1 x 1011

1 x 1
XANES, PES

operational

X1B

0.2 - 1.6

.

0.05 x 2
XAS, PES, XES, RIXS

operational

 X3B  3.8-13.3
 9 x 1011  0.2 x 0.7
 XAFS, dilute elements
 operational

X10C

4 - 24

1 x 1010

0.5 x 10
General purpose XAFS

Closed

X11A

4.5 - 40

1 x 1011

0.5 x 10
General purpose XAFS

operational

 X11B  5 - 23
   0.5 x 20
 General purpose XAFS
 operational

X15B

1.2 - 8

1012

1 x 1
General purpose XAFS, dilute elements,
surface science

operational

X18B

4.8 - 40

1 x 1010

1.5 x 25
General purpose

operational

X19A

2.1 - 17

5 x 1010

1 x 2
General purpose, resonant XRD

operational

X23A2

4.7 - 30

1 x 1010

1 x 25
General purpose,
powder XRD,
DAFS

operational

 X24A  1.8 - 6
 approx 1012  1 mm diameter
 General purpose XAFS, PES, DAFS
 operational

X24C

0.006 - 1.8

109 - 1012

1 x 2
XANES, PES,
reflectivity

Closed

 ; NSLS updated 10 March 2014

SRC

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

CSRF
Double crystal

1.5 - 4

.

2 x 2
general purpose

Closed

  SRC   checked 11 February 2012

SSRL

Beamline

Energy Range [keV]

Flux
[photons/s]

Beam size at sample
V x H [mm2]

Purpose

Status

2-3

4.5 - 24

1010

2 μm x 2 μm
microXAFS

Operational

4-1

5.5 - 38

.

4 x 18
General purpose

Operational

4-3

2.4 - 14

.

3 x 16
General purpose

Operational

6-2a

2.3 - 17

.

0.5 x 0.5

-------

2 x 20

General purpose

-----

XES, RIXS

Operational

7-3

4.6 - 37

1012

2 x 15
BioXAS

Operational

8-2

0.1 - 1.3

.

0.1 mm spot size
XANES, PES

Operational

9-3

5 - 30

2 1012

0.5 x 3
BioXAS

Operational

10-1

0.25 - 1.2

.

1 mm spot size
XANES, PES

Operational

10-2a

4.5 - 45

.

0.2 x 0.45

-----

2 x 20

General purpose

Operational

11-2

4.5 - 37

.

0.5 x 3

----

2 x 30

General purpose, GIXAFS

Operational

 13-2 0.25 - 1.1
  0.01 x 0.075
XANES, surface science
 Operational
 14-3  2 - 5
     General purpose
available during 2010

 

  SSRL   checked 11 February 2012


These pages are maintained by the Commission Last updated: 15 Oct 2021