IUCr CPD Round Robin on Quantitative Phase Analysis
Introduction
The CPD-QARR homepage is now located at http://www.iucr.org/resources/commissions/powder-diffraction/projects/qarr
Weighed and Measured Values of Distributed Samples and Data (released on the web, 8th November 1999)
Initiated and Organized by the IUCr Commission on Powder Diffraction
Aims of the Round Robin
The round robin will focus on the analysis of powder diffraction data specifically for the derivation of quantitative phase abundance. While the study will focus on the use of laboratory X-ray, synchrotron X-ray and neutron diffraction data, other methods may be used to validate the diffraction results (e.g. FTIR, normative analysis, etc.). The additional methods used will be at the discretion of the participant.
General aims
The general goals of the round robin will include the following:
- To document the methods & strategies commonly employed in Quantitative Phase Analysis (QPA), especially those involving powder diffraction
- To assess (i) levels of accuracy & precision, and (ii) lower limits of detection
- To identify specific problem areas & develop practical solutions
- To formulate recommended procedures for QPA using diffraction data
- To create a standard set of samples for future reference
Specific aims
The round robin will address the following analytical issues:
- Type of analysis:
- diffraction (X-ray /Neutron) vs non-diffraction internal std vs external std vs spiking etc standardless methods
- Sample features
- representivity & homogeneity
- particle & crystallite size
- statistics & microabsorption
- crystallinity & surface roughness
- preferred orientation, microabsorption & extinction
- Data collection
- type of instrument / geometry
- sample preparation
- data range and wavelength
- Data analysis
- integrated intensities vs full-profile Rietveld vs data-base of observed patterns
- use of constraints and corrections
- software systems & methods
- complexity of the pattern - peak overlap
Possible levels of participation will include the following:
Diffraction data only
Participant analyses 'standard' data sets supplied by the CPD and returns details of the analytical procedure plus the results.
Get the Standard Powder X-ray Diffraction Data Sets via the web
Prepared samples
Participant collects own data for analysis from at least two of the samples supplied by the CPD ('simple' and 'preferred orientation')
Unprepared samples
Samples supplied by the CPD are representative of bulk, but may need additional preparation. Participant prepares samples for data collection and analysis.
Since the purpose of the round robin is to assess the methods of quantification, and not identification, the identity of each of the component phases will be supplied. For those participants using Rietveld based methods for the analysis, full structural information for each of the phases will also be supplied. Participants will be asked to return the results using 'standard' reporting forms. This should minimize the number of errors likely to occur during transcription of the data. In addition, it is requested that the diffraction data be returned to the CPD as an ASCII format file for re-analysis with a 'standard' Rietveld code.
Timeline - Initial Round of Samples went out in Early Jan 1998
The following timeline for the round robin is proposed:
August / September 1996
Final recommendations for mixtures and protocol Formal approval from CPD
August 96 - March 97
Call for expressions of interest
Samples sourced & prepared for distribution
Collection of standard data
Questionnaire sent to all participants
June 97
Samples and data distributed to participants
December 97
Call-in of results
January - June 98
Analysis of results (including late submissions)
August 98
Preliminary results presented at EPDIC-6
August 99
Presentation of final results at Glasgow IUCr Congress
How to participate
After deciding what you would like to analyse, contact us by email or any method you prefer. Details should include Name, Affiliation, Postal address, Phone and FAX numbers (including country and area codes), Email address. Extra information should include information about which of the samples you wish to analyze plus the amount of sample required (i.e. are they an X-ray, neutron user, XRF, IR, Wet Chemical, etc).
Operating Team
- Ian Madsen - CSIRO Minerals, Australia
- Rod Hill - CSIRO Minerals, Australia
- Edward Groleau - Eli Lilly & Co, USA
- Lachlan Cranswick - Melbourne, Australia (Now Daresbury Lab - U.K.)
Advisory Team
- Deane Smith (CPD) - Penn State University, USA
- Jaroslav Fiala - Central Res. Inst., Czech Rep.
Contact Details for all Correspondence
Ian MadsenCSIRO Minerals
Box 312 Clayton South 3169
Victoria AUSTRALIA
Phone +61 3 9545 8785 direct
Phone +61 3 9545 8500 switch
FAX +61 3 9562 8919
Email qpa.rr@minerals.csiro.au (for the round robin)
Ian.Madsen@ minerals.csiro.au (for all other correspondence)
Web: http://www.dl.ac.uk/SRS/XRD/IUCR/QARR/
Get the Standard Powder X-ray Diffraction Data Sets via the web
These pages were constructed as part of an International Union of Crystallography Commission on Powder Diffraction project. They are no longer actively maintained.