_diffrn_scan_frame_axis.reference_displacement
Name:_diffrn_scan_frame_axis.reference_displacement
Definition:
The setting of the specified axis in millimetres for this
frame against which measurements of the reference beam center
and reference detector distance should be made.
This is normally the same for all frames, but the
option is provided here of making changes when
needed.
If not provided, it is assumed to be equal to
_diffrn_scan_frame_axis.displacement.
Type: Real
Units: millimetres
Category:
diffrn_scan_frame_axis